On joist centres up to 450 mm, 18 mm panels may be used, but on joist centres up to 600 mm, 22 mm panels must be used.
Board | Max span (mm) | Qk Uniformaly distributed load kN/m2 |
QK Concentrated point load kN SC1 |
QK Concentrated point load kN SC2 |
18mm P5 | 450 | 11.3 | 3.7 | 2.6 |
22mm P5 | 600 | 3.2 | 3.0 | 2.0 |
Click here to find out more.