EGGER Flammex Laminate meets the specific requirements of building materials class B1 in accordance with DIN 4102-1: 1998-05 as well as the French fire behaviour class M1 in accordance with NF P 92-501.
As flammex laminate is generally used for the lamination of laminated bonded boards, please note that any reference to fire classifications relates to the laminate only. The adhesive and substrate that the laminate is bonded to will impact on the overall rating of any finished goods - the combination of the structure and the surface provides the classification.
In the event of a fire, the laminated bonded boards meet the special requirements of EN 13501-1/ B-S2, d0, providing that the following materials have been used:
- Substrate: Eurospan Flammex (fire resistant raw board)
- Glue system: appropriate fire resistant adhesive
- Lamination: EGGER Laminate Flammex
For more information on the Fire behaviour please view our EGGER Flammex Laminate Technical datasheet here.
To see our Environmental Product Declaration (EPD) Laminate Flammex click here.